<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">helmholtzeyeinstitute</journal-id><journal-title-group><journal-title xml:lang="ru">Российский офтальмологический журнал</journal-title><trans-title-group xml:lang="en"><trans-title>Russian Ophthalmological Journal</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2072-0076</issn><issn pub-type="epub">2587-5760</issn><publisher><publisher-name>Real time Publishers</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21516/2072-0076-2023-16-1-29-35</article-id><article-id custom-type="elpub" pub-id-type="custom">helmholtzeyeinstitute-1164</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>КЛИНИЧЕСКИЕ ИССЛЕДОВАНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>CLINICAL STUDIES</subject></subj-group></article-categories><title-group><article-title>Сравнительный анализ результатов коррекции роговичного астигматизма торическими ИОЛ с применением различных методов разметки</article-title><trans-title-group xml:lang="en"><trans-title>A comparative analysis of the results of corneal astigmatism correction by toric IOL using various markup methods</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Иошин</surname><given-names>И. Э.</given-names></name><name name-style="western" xml:lang="en"><surname>Ioshin</surname><given-names>I. E.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Игорь Эдуардович Иошин — д-р мед. наук, профессор, заведующий Центра офтальмологии</p><p>ул. Лосиноостровская, д. 45, Москва, 107150</p></bio><bio xml:lang="en"><p>Igor E. Ioshin — Dr. of Med. Sci., professor, head of the Center ophthalmology</p><p>45, Losinoostrovskaya St., Moscow, 107150</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Мурашев</surname><given-names>А. О.</given-names></name><name name-style="western" xml:lang="en"><surname>Murashev</surname><given-names>A. O.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Александр Олегович Мурашев — врач-офтальмолог</p><p>ул. Димитрова, д. 2б, Ковров, 601900</p></bio><bio xml:lang="en"><p>Alexander O. Murashev — ophthalmologist</p><p>2B, Dimitrov St., Kovrov, 601900</p></bio><email xlink:type="simple">89100906300@yandex.ru</email><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Демин</surname><given-names>А. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Demin</surname><given-names>A. N.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Алексей Николаевич Демин — врач-офтальмолог</p><p>ул. Марии Ульяновой, д. 13, Вологда, 160000</p></bio><bio xml:lang="en"><p>Alexey N. Demin — ophthalmologist</p><p>13, Maria Ulyanova St., Vologda, 160000</p></bio><xref ref-type="aff" rid="aff-3"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБУ «Клиническая больница» Управления делами Президента Российской Федерации</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Clinical Hospital of the Office of the President’s Affairs</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ООО «Ковровская глазная клиника "Био Абсолют"»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Kovrov Eye Clinic “Bio Absolut”</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-3"><aff xml:lang="ru"><institution>ООО «Вологодская глазная клиника "Визус-Абсолют"»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Vologda Eye Clinic “Vizus Absolut”</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2023</year></pub-date><pub-date pub-type="epub"><day>14</day><month>03</month><year>2023</year></pub-date><volume>16</volume><issue>1</issue><fpage>29</fpage><lpage>35</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Иошин И.Э., Мурашев А.О., Демин А.Н., 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">Иошин И.Э., Мурашев А.О., Демин А.Н.</copyright-holder><copyright-holder xml:lang="en">Ioshin I.E., Murashev A.O., Demin A.N.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://roj.igb.ru/jour/article/view/1164">https://roj.igb.ru/jour/article/view/1164</self-uri><abstract><p>Цель работы — проанализировать результаты коррекции роговичного астигматизма в хирургии катаракты при использовании двух методов разметки расчетной оси торической ИОЛ с применением векторного анализа Alpins. Материал и методы. В ретроспективную группу исследования вошли 212 пациентов (259 глаз) с катарактой и исходным роговичным астигматизмом от 0,75 до 8,25 дптр. Пациентам были имплантированы торические ИОЛ: AlconAcrysofToric (113 пациентов, 135 глаз) и ZeissATTorbi 709M (99 пациентов, 124 глаза). Расчет ИОЛ проводился на оптическом биометре IOLMaster 500 (Carl Zeiss), целевая рефракция — эмметропия. Расчет оси положения торической ИОЛ определялся на онлайн-калькуляторах фирм-производителей. Пациенты были разделены на две группы в соответствии с методом разметки: в 1-й группе (149 глаз) разметка проводилась по авторской методике с использованием угловой шкалы щелевой лампы, во 2-й (110 глаз) — с применением навигационных систем Verion (Alcon) и CallistoEye (Zeiss). Для оценки эффективности коррекции астигматизма использовался метод векторного анализа по Alpins. Результаты. В обеих группах после операции выявлено значительное повышение некорригируемой (НКОЗ) и максимально корригируемой (МКОЗ) остроты зрения. В 1-й группе через месяц после операции НКОЗ составила 0,67 ± 0,19, МКОЗ — 0,80 ± 0,17. Во 2-й группе НКОЗ составила 0,690 ± 0,065, МКОЗ — 0,80 ± 0,49. Индекс успеха (IOS) был равен 0,14 в 1-й группе и 0,11 — во 2-й группе. Вектор различия (DV) составил 0,37 и 0,31 дптр соответственно в обеих группах, что говорит о высокой точности коррекции астигматизма. Среднее значение угла ошибки (AOfE) в 1-й группе составило 3,29° и во 2-й группе — 3,29°, среднее значение вектора целевого астигматизма (TIA) в 1-й группе — 2,69 ± 1,01 дптр по оси 87,3°, во 2-й группе — 2,75 ± 1,09 дптр по оси 95,1°, среднее значение вектора хирургически исправленного астигматизма (SIA) в 1-й группе — 2,32 ± 0,99 дптр по оси 87°, во 2-й группе — 2,44 ± 1,03 дптр по оси 99,6°. Заключение. Применение авторского способа разметки торических ИОЛ с применением угловой шкалы щелевой лампы позволяет получить высокие функциональные результаты коррекции роговичного астигматизма. Сравнительный векторный анализ двух групп исследования показывает сопоставимые результаты предложенного типа разметки и разметки интраоперационными навигационными системами.</p></abstract><trans-abstract xml:lang="en"><p>Purpose: to analyze the results of corneal astigmatism correction by cataract surgery using two methods of marking the calculated toric IOL axis with Alpins vector analysis. Materials and methods. The retrospective study group included 212 patients (259 eyes) with cataracts and baseline corneal astigmatism from 0.75 to 8.25 D. The patients were implanted with two varieties of toric IOLs: Alcon Acrysof Toric (113 patients, 135 eyes) and Zeiss AT Torbi 709M (99 patients, 124 eyes). IOL parameters were calculated using an IOLMaster 500 (Carl Zeiss) optical biometer, the target refraction being emmetropy. The axis of toric IOL alignment was determined by online calculators provided by the producers. The patients were divided into two groups in accordance with the marking method: group 1 patients (149 eyes) were marked using by the authors’ techniques that used the angular scale of the slit lamp, while group 2 (110 eyes) was treated with Verion (Alcon) and Callisto Eye (Zeiss) navigation systems. The effectiveness of astigmatism correction was assessed using the Alpins vector analysis method. Results. After surgery, both groups showed a significant increase in uncorrected (UCVA) and best corrected visual acuity (BCVA). In group 1, one month after the operation, the UCVA was 0.67 ± 0.19, and the BCVA was 0.80 ± 0.17. In group 2, UCVA was 0.69 ± 0,07, and BCVA was 0.80 ± 0.49. The success index (IOS) was 0.14 in group 1 and 0.11 in group 2. The difference vector (DV) in the two groups was 0.37 and 0.31 D, respectively, suggesting highly precise astigmatism correction. The average error angle (AOfE) in group 1 was 3.29°, and in group 2 — 3.29°. The average value of the TIA vector was 2.69 ± 1.01 D along the axis of 87.3°, in group 1, while that of group 2 was 2.75 ± 1.09 D along the axis of 95.1°. The average values of the SIA vector were 2.32 ± 0.99 D along the axis of 870 in group 1 and — 2.44 ± 1.03 D along the axis of 99.6° in group 2. Conclusion. The authors’ markup method using the angular scale of the slit lamp yields high functional results of corneal astigmatism correction. The comparative vector analysis of the two study groups shows similar results in applying the authors’ type of markup and that of intraoperative navigation systems.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>роговичный астигматизм</kwd><kwd>векторный анализ Альпинса</kwd><kwd>факоэмульсификация</kwd><kwd>торическая ИОЛ</kwd></kwd-group><kwd-group xml:lang="en"><kwd>corneal astigmatism</kwd><kwd>Alpins vector analysis</kwd><kwd>phacoemulsification</kwd><kwd>toric IOL</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Hashemi H., Rezvan F., Yekta A.A., et al. The prevalence of astigmatism and its determinants in a rural population of Iran: the “Nooravaran Salamat” mobile eye clinic experience. Middle East. Afr. J. Ophthalmol. 2014; 21 (2): 175–81. doi: 10.4103/0974-9233.129772</mixed-citation><mixed-citation xml:lang="en">Hashemi H., Rezvan F., Yekta A.A., et al. The prevalence of astigmatism and its determinants in a rural population of Iran: the “Nooravaran Salamat” mobile eye clinic experience. Middle East. Afr. J. Ophthalmol. 2014; 21 (2): 175–81. doi: 10.4103/0974-9233.129772</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Varssano D. Etiology and clinical presentation of astigmatism. In: Goggin M., eds. Astigmatism — Optics, Physiology and Management. London; 2012: 15-32. doi:10.5772/18338</mixed-citation><mixed-citation xml:lang="en">Varssano D. Etiology and clinical presentation of astigmatism. In: Goggin M., eds. Astigmatism — Optics, Physiology and Management. London; 2012: 15-32. doi:10.5772/18338</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Астахов С.Ю., Хрипун К.В. Коррекция астигматизма при высоких степенях астигматизма — какой способ выбрать? Офтальмологические ведомости. 2014; 7 (2): 9–12. doi: https://doi.org/10.17816/OV201429-12</mixed-citation><mixed-citation xml:lang="en">Astakhov S.Ju., Hripun K.V. Correction of high astigmatism ’s degrees — what method would be choose? Oftal'mologicheskie vedomosti. 2014; 7 (2): 9–12 (in Russian). doi: https://doi.org/10.17816/OV201429-12</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Федяшев Г.А. Коррекция астигматизма дорическими интраокулярными линзами у пациентов, оперирующихся по поводу катаракты. Офтальмология. 2013; 10 (2): 8–12.</mixed-citation><mixed-citation xml:lang="en">Fedjashev G.A. Correction of astigmatism by toric IOLs for patients with cataract. Oftal'mologija. 2013; 10 (2): 8–12 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Holladay J.T. Exact toric intraocular lens calculations using currently available lens constants. Arch. Ophthalmol. 2012; 130 (7): 946–47; author reply 948–9. doi: 10.1001/archophthalmol.2011.1917</mixed-citation><mixed-citation xml:lang="en">Holladay J.T. Exact toric intraocular lens calculations using currently available lens constants. Arch. Ophthalmol. 2012; 130 (7): 946–47; author reply 948–9. doi: 10.1001/archophthalmol.2011.1917</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Бачук Н.Ю. Опыт имплантации торических интраокулярных линз у больных катарактами с роговичным астигматизмом. Международный медицинский журнал. 2013; 1: 63–6.</mixed-citation><mixed-citation xml:lang="en">Bachuk N.Ju. Experience of toxic IOLs implantation for patients with cataracts and corneal astigmatism. Mezhdunarodnyj medicinskij zhurnal. 2013; 1: 63–6 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Трубилин В.Н., Ильинская И.А., Трубилин А.В. Интраокулярная коррекция роговичного астигматизма в ходе хирургии катаракты. Обзор литературы. Катарактальная и рефракционная хирургия. 2014; 14 (3): 4–10.</mixed-citation><mixed-citation xml:lang="en">Trubilin V.N., Il'inskaja I.A., Trubilin A.V. Intraocular correction of corneal astigmatism in cataract surgery. Obzor literatury. Kataraktal'naja i refrakcionnaja hirurgija. 2014; 14 (3): 4–10 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Assaf A., Qabeel M.A.F., Zaki J.M. Analysis of ocular cyclotorsion in lying position after peribulbar block. Medical Journal of Cairo University. 2020; 88 (3): 933–8. doi: 10.21608/mjcu.2020.105127.</mixed-citation><mixed-citation xml:lang="en">Assaf A., Qabeel M.A.F., Zaki J.M. Analysis of ocular cyclotorsion in lying position after peribulbar block. Medical Journal of Cairo University. 2020; 88 (3): 933–8. doi: 10.21608/mjcu.2020.105127.</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Кирносов С.В. Интраокулярная коррекция астигматизма. Способы разметки его оси. Медицинский вестник Башкортостана. 2018; 13 (1) (73): 122–6.</mixed-citation><mixed-citation xml:lang="en">Kirnosov S.V. Intraocular correction of astigmatism. The methods of marking. Medicinskij vestnik Bashkortostana. 2018; 13 (1) (73): 122–6 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Cha D., Kang S.Y., Kim S.H., et al. New axis-marking method for a toric intraocular lens: mapping method. J. Refract. Surg. 2011; 27 (5): 375–9. doi: 10.3928/1081597X-20101005-01</mixed-citation><mixed-citation xml:lang="en">Cha D., Kang S.Y., Kim S.H., et al. New axis-marking method for a toric intraocular lens: mapping method. J. Refract. Surg. 2011; 27 (5): 375–9. doi: 10.3928/1081597X-20101005-01</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Devgan U. Ocular Surgery News Europe Edition. 2011; 22 (2): 22.</mixed-citation><mixed-citation xml:lang="en">Devgan U. Ocular Surgery News Europe Edition. 2011; 22 (2): 22.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Трубилин В.Н., Копаев С.Ю., Ильинская И.А. Оптимизированная методика разметки оси имплантации торической интраокулярной линзы у пациента с увеальной катарактой (клинический случай). Сибирский научный медицинский журнал. 2014; 5: 93–6.</mixed-citation><mixed-citation xml:lang="en">Trubilin V.N., Kopaev S.Ju., Il'inskaja I.A. The optimisation method of marking axis of topic IOL for patient with uveal cataract. (clinical case). Sibirskij nauchnyj medicinskij zhurnal. 2014; 5: 93–6 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Малюгин Б.Э. Хирургия катаракты и интраокулярная коррекция на современном этапе развития офтальмохирургии. Вестник офтальмологии. 2014; 130 (6): 80–8.</mixed-citation><mixed-citation xml:lang="en">Maljugin B.E. Cataract surgery and intraocular correction in the modern stage of ophthalmology progress. Vestnik oftal'mologii. 2014; 130 (6): 80–8 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Терещенко А.В., Трифаненкова И.Г., Окунева М.В. и др. Хирургическая коррекция астигматизма в ходе факоэмульсификации катаракты с применением системы VERION. Офтальмохирургия. 2018; 2: 23–9. doi: 10.25276/0235-4160-2018-2-23-29</mixed-citation><mixed-citation xml:lang="en">Tereshhenko A.V., Trifanenkova I.G., Okuneva M.V., et al. Surgical astigmatism correction in phacoemulsification of cataract with using VERION system. Oftal'mohirurgija. 2018; 2: 23–9 (in Russian). doi: 10.25276/0235-4160-2018-2-23-29</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Alpins N. Astigmatism analysis by the alpins method. J. Cataract. Refract. Surg. 2001; 27 (1): 31–49. doi 10.1016/s0886-3350(00)00798-7</mixed-citation><mixed-citation xml:lang="en">Alpins N. Astigmatism analysis by the alpins method. J. Cataract. Refract. Surg. 2001; 27 (1): 31–49. doi 10.1016/s0886-3350(00)00798-7</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Иошин И.Э., Мурашев А.О. Способ позиционирования торической интраокулярной линзы при имплантации. Патент РФ на изобретение № 2643417от 01.02.2018.</mixed-citation><mixed-citation xml:lang="en">Ioshin I.E., Murashev A.O. Method for positioning a toric intraocular lens during implantation. RU Patent № 2643417, 01.02.2018 (in Russian).</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
