<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">helmholtzeyeinstitute</journal-id><journal-title-group><journal-title xml:lang="ru">Российский офтальмологический журнал</journal-title><trans-title-group xml:lang="en"><trans-title>Russian Ophthalmological Journal</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2072-0076</issn><issn pub-type="epub">2587-5760</issn><publisher><publisher-name>Real time Publishers</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21516/2072-0076-2023-16-1-168-174</article-id><article-id custom-type="elpub" pub-id-type="custom">helmholtzeyeinstitute-1188</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>ОБЗОРЫ ЛИТЕРАТУРЫ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>REVIEWS</subject></subj-group></article-categories><title-group><article-title>Особенности применения традиционной аналоговой и трехмерной цифровой визуализации в офтальмохирургии</article-title><trans-title-group xml:lang="en"><trans-title>Traditional analogue vs. three-dimensional digital visualization used in ophthalmic surgery</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Стебнев</surname><given-names>В. С.</given-names></name><name name-style="western" xml:lang="en"><surname>Stebnev</surname><given-names>V. S.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Вадим Сергеевич Стебнев — д-р мед. наук, профессор кафедры глазных болезней;  главный врач</p><p>ул. Чапаевская, д. 89, Самара, 443099; ул. Самарская, д. 25, Самара, 443020</p></bio><bio xml:lang="en"><p>Vadim S. Stebnev — Dr. of Med. Sci., professor of the department of eye diseases;  chief medical officer</p><p>89, Chapaevskaya St., Samara 443099; 25, Samarskaya St., Samara, 443020</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Журавлев</surname><given-names>А. В.</given-names></name><name name-style="western" xml:lang="en"><surname>Zhuravlev</surname><given-names>A. V.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Антон Владимирович Журавлев — аспирант кафедры глазных болезней; врач-офтальмолог</p><p>ул. Чапаевская, д. 89, Самара, 443099; ул. Светлая, д. 12, Кинель, Самарская область, 446430</p></bio><bio xml:lang="en"><p>Anton V. Zhuravlev — PhD student of the department of eye diseases; ophthalmologist</p><p>89, Chapaevskaya St., Samara 443099; 12, Svetlaya St., Kinel, Samara region, 446430</p></bio><email xlink:type="simple">zhuranton@inbox.ru</email><xref ref-type="aff" rid="aff-2"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБОУ «Самарский государственный медицинский университет — Институт профессионального образования»; Офтальмологическая клиника «Хирургия глаза»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Samara State Medical University, Institute of Vocational Education;  “Eye Surgery” Ophthalmological Clinic</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>ФГБОУ «Самарский государственный медицинский университет — Институт профессионального образования»; ГБУЗ СО «Кинельская ЦБГиР»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Samara State Medical University, Institute of Vocational Education; Kinel Central Regional Hospital</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2023</year></pub-date><pub-date pub-type="epub"><day>18</day><month>03</month><year>2023</year></pub-date><volume>16</volume><issue>1</issue><fpage>168</fpage><lpage>174</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Стебнев В.С., Журавлев А.В., 2023</copyright-statement><copyright-year>2023</copyright-year><copyright-holder xml:lang="ru">Стебнев В.С., Журавлев А.В.</copyright-holder><copyright-holder xml:lang="en">Stebnev V.S., Zhuravlev A.V.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://roj.igb.ru/jour/article/view/1188">https://roj.igb.ru/jour/article/view/1188</self-uri><abstract><p>Визуализация хирургического процесса остается актуальной проблемой оперативного лечения катаракты. В обзоре представлена история методов визуализации в офтальмохирургии, проведено сравнение основных современных аналоговых и трехмерных цифровых технологий. Появление в клинической практике 3D-систем визуализации позволило решить многие проблемы, возникавшие при использовании стандартных аналоговых микроскопов. К таким проблемам можно отнести ограниченные фокус и поле зрения, необходимость яркого освещения, увеличивающего риск ятрогенной ретинальной фототоксичности, постоянное использование хирургом бинокуляров микроскопа и, как следствие, большую нагрузку на его зрительный аппарат, а также мышцы спины и шеи.</p></abstract><trans-abstract xml:lang="en"><p>The visualization of the surgical process remains a topical issue in cataract surgery. The review presents the history of visualization technique in ophthalmic surgery and compares the main current analogue and 3D digital technologies. The advent of 3D imaging systems in clinical practice has helped solve many issues associated with the use of standard analogue microscopes. These issues include limited focus and field of vision, the need to use a large amount of light, which increases the risk of iatrogenic retinal phototoxicity, the surgeon's attachment to the microscope and, consequently, a high load on the surgeon's visual apparatus when using eyepieces, as well as on their back and neck muscles.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>визуализация</kwd><kwd>офтальмохирургия</kwd><kwd>катаракта</kwd></kwd-group><kwd-group xml:lang="en"><kwd>visualization</kwd><kwd>ophthalmic surgery</kwd><kwd>cataract</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Kriss T.C., Kriss V.M. History of the operating microscope: from magnifying glass to microneurosurgery. 1998; 42 (4): 899–907. doi: 10.1097/00006123- 199804000-00116</mixed-citation><mixed-citation xml:lang="en">Kriss T.C., Kriss V.M. History of the operating microscope: from magnifying glass to microneurosurgery. 1998; 42 (4): 899–907. doi: 10.1097/00006123- 199804000-00116</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Bradbury S. The evolution of the microscope. New York: Pergamon, 1967.</mixed-citation><mixed-citation xml:lang="en">Bradbury S. The evolution of the microscope. New York: Pergamon, 1967.</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Kalderon A.E. The evolution of microscope design from its invention to the present days. Am. J. Surg. Pathol. 1983; 7 (1): 95–102.</mixed-citation><mixed-citation xml:lang="en">Kalderon A.E. The evolution of microscope design from its invention to the present days. Am. J. Surg. Pathol. 1983; 7 (1): 95–102.</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">James P., Nick J. Thorpe. Ancient inventions. Ballantine: Books Inc.; 1997.</mixed-citation><mixed-citation xml:lang="en">James P., Nick J. Thorpe. Ancient inventions. Ballantine: Books Inc.; 1997.</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Соболь С.Л. Изобретение микроскопа и его исторические предпосылки. Москва; 1945: 418–9. [Sobol S.L. The invention of the microscope and its historical background. Moscow; 1945: 418–9 (In Russian)].</mixed-citation><mixed-citation xml:lang="en">Соболь С.Л. Изобретение микроскопа и его исторические предпосылки. Москва; 1945: 418–9. [Sobol S.L. The invention of the microscope and its historical background. Moscow; 1945: 418–9 (In Russian)].</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Kalderon A.E. The evolution of microscope design from its invention to the present days. Am. J. Surg. Pathol. 1983; 7 (1): 95–102.</mixed-citation><mixed-citation xml:lang="en">Kalderon A.E. The evolution of microscope design from its invention to the present days. Am. J. Surg. Pathol. 1983; 7 (1): 95–102.</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Purtle H.R. History of the microscope. In: Gray P., eds. The encyclopedia of microscopy and microtechnique. New York: Van Nostrand Reinhold; 1973: 252–60.</mixed-citation><mixed-citation xml:lang="en">Purtle H.R. History of the microscope. In: Gray P., eds. The encyclopedia of microscopy and microtechnique. New York: Van Nostrand Reinhold; 1973: 252–60.</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Zuylen J.V. The microscopes of Antoni van Leeuwenhoek. J. Microsc. 1981; 309–28. doi: 10.1111/j.1365-2818.1981.tb01227.x</mixed-citation><mixed-citation xml:lang="en">Zuylen J.V. The microscopes of Antoni van Leeuwenhoek. J. Microsc. 1981; 309–28. doi: 10.1111/j.1365-2818.1981.tb01227.x</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Landolt I.E. Review of surgical loupes. In: Handbuch der Augenheilunde. Berlin: Springer; 1920: 353–61.</mixed-citation><mixed-citation xml:lang="en">Landolt I.E. Review of surgical loupes. In: Handbuch der Augenheilunde. Berlin: Springer; 1920: 353–61.</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Schultheiss D., Denil J. History of the microscope and development of microsurgery: a revolution for reproductive tract surgery. Andrologia. 2002; 34 (4): 234–41. doi: 10.1046/j.1439-0272.2002.00499.x</mixed-citation><mixed-citation xml:lang="en">Schultheiss D., Denil J. History of the microscope and development of microsurgery: a revolution for reproductive tract surgery. Andrologia. 2002; 34 (4): 234–41. doi: 10.1046/j.1439-0272.2002.00499.x</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Perritt R.A. The operating microscope in practice. Bibl. Ophthamol. 1968; 77: 21–50.</mixed-citation><mixed-citation xml:lang="en">Perritt R.A. The operating microscope in practice. Bibl. Ophthamol. 1968; 77: 21–50. 12. Perritt R.A. Micro Ophthalmic Surgery. Belgica Acta. 1958; 2: 1680–3.</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Perritt R.A. Micro Ophthalmic Surgery. Belgica Acta. 1958; 2: 1680–3.</mixed-citation><mixed-citation xml:lang="en">Jackson E. Magnifying lenses for use when operating. 1897. Arch. Ophthalmol. 1996; 114 (7): 867–8. doi: 10.1001/archopht.1996.01100140081014</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Jackson E. Magnifying lenses for use when operating. 1897. Arch. Ophthalmol. 1996; 114 (7): 867–8. doi: 10.1001/archopht.1996.01100140081014</mixed-citation><mixed-citation xml:lang="en">Schultheiss D., Denil J. History of the microscope and development of microsurgery: a revolution for reproductive tract surgery. Andrologia. 2002; 34 (4): 234–41. doi: 10.1046/j.1439-0272.2002.00499.x</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Schultheiss D., Denil J. History of the microscope and development of microsurgery: a revolution for reproductive tract surgery. Andrologia. 2002; 34 (4): 234–41. doi: 10.1046/j.1439-0272.2002.00499.x</mixed-citation><mixed-citation xml:lang="en">Czapski S. Binokulares Corneal Mikroskop. Graefe Arch. Ophthalmol. 1899; 48: 229–35.</mixed-citation></citation-alternatives></ref><ref id="cit15"><label>15</label><citation-alternatives><mixed-citation xml:lang="ru">Czapski S. Binokulares Corneal Mikroskop. Graefe Arch. Ophthalmol. 1899; 48: 229–35.</mixed-citation><mixed-citation xml:lang="en">Barraquer J.I. The microscope in ocular surgery. Am. J. Ophthalmol. 1956; 42 (6): 916–8. doi: 10.1016/0002-9394(56)90666-3</mixed-citation></citation-alternatives></ref><ref id="cit16"><label>16</label><citation-alternatives><mixed-citation xml:lang="ru">Barraquer J.I. The microscope in ocular surgery. Am. J. Ophthalmol. 1956; 42 (6): 916–8. doi: 10.1016/0002-9394(56)90666-3</mixed-citation><mixed-citation xml:lang="en">Nylean C.O. The microscope in aural surgery, its first use and later development. Acta Otolaryngol. Suppl. 1954; 226–40.</mixed-citation></citation-alternatives></ref><ref id="cit17"><label>17</label><citation-alternatives><mixed-citation xml:lang="ru">Nylean C.O. The microscope in aural surgery, its first use and later development. Acta Otolaryngol. Suppl. 1954; 226–40.</mixed-citation><mixed-citation xml:lang="en">Tang C.T., Kurozumi, K., Pillai, et al. Quantitative analysis of surgical exposure and maneuverability associated with the endoscope and the microscope in the retrosigmoid and various posterior petrosectomy approaches to the petroclival region using computer tomograpy-based frameless stereotaxy. A cadaveric study. Clin. Neurol. Neurosurg, 2013; 115 (7): 1058–62. doi: 10.1016/j.clineuro.2012.10.023</mixed-citation></citation-alternatives></ref><ref id="cit18"><label>18</label><citation-alternatives><mixed-citation xml:lang="ru">Tang C.T., Kurozumi, K., Pillai, et al. Quantitative analysis of surgical exposure and maneuverability associated with the endoscope and the microscope in the retrosigmoid and various posterior petrosectomy approaches to the petroclival region using computer tomograpy-based frameless stereotaxy. A cadaveric study. Clin. Neurol. Neurosurg, 2013; 115 (7): 1058–62. doi: 10.1016/j.clineuro.2012.10.023</mixed-citation><mixed-citation xml:lang="en">Ulu K., Kujoth G.C., Ba kaya M.K. Operating microscopes: past, present, and future. Neurosurg. Focus. 2009; 27 (3): E 4. doi: 10.3171/2009.6.focus09120</mixed-citation></citation-alternatives></ref><ref id="cit19"><label>19</label><citation-alternatives><mixed-citation xml:lang="ru">Ulu K., Kujoth G.C., Ba kaya M.K. Operating microscopes: past, present, and future. Neurosurg. Focus. 2009; 27 (3): E 4. doi: 10.3171/2009.6.focus09120</mixed-citation><mixed-citation xml:lang="en">Korolyuk I.P. Medical informatics. Samara: OOO «Ofort»; 2012 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit20"><label>20</label><citation-alternatives><mixed-citation xml:lang="ru">Королюк И.П. Медицинская информатика. Самара: ООО «Офорт»; 2012.</mixed-citation><mixed-citation xml:lang="en">Miron H., Blumenthal E.Z. Bridging analog and digital video in the surgical setting. J. Cataract Refract. Surg. 2003; 29 (10): 1874–7. doi: 10.1016/s0886- 3350(03)00252-9</mixed-citation></citation-alternatives></ref><ref id="cit21"><label>21</label><citation-alternatives><mixed-citation xml:lang="ru">Miron H., Blumenthal E.Z. Bridging analog and digital video in the surgical setting. J. Cataract Refract. Surg. 2003; 29 (10): 1874–7. doi: 10.1016/s0886- 3350(03)00252-9</mixed-citation><mixed-citation xml:lang="en">Buckland E.L. Surgical microscopes using optical coherence tomography and related methods. Patent US # 8, 777, 412 B2; 2014.</mixed-citation></citation-alternatives></ref><ref id="cit22"><label>22</label><citation-alternatives><mixed-citation xml:lang="ru">Buckland E.L. Surgical microscopes using optical coherence tomography and related methods. Patent US # 8, 777, 412 B2; 2014.</mixed-citation><mixed-citation xml:lang="en">Riew K.D., McCulloch J.A., Delamarter R.B., An H.S., Ahn N.U. Microsurgery for degenerative conditions of the cervical spine. Instruct. Course Lect. 2003; 52: 497–508.</mixed-citation></citation-alternatives></ref><ref id="cit23"><label>23</label><citation-alternatives><mixed-citation xml:lang="ru">Riew K.D., McCulloch J.A., Delamarter R.B., An H.S., Ahn N.U. Microsurgery for degenerative conditions of the cervical spine. Instruct. Course Lect. 2003; 52: 497–508.</mixed-citation><mixed-citation xml:lang="en">Dhimitri K.C., McGwin G.Jr., McNeal S.F., et al. Symptoms of musculoskeletal disorders in ophthalmologists. Am. J. Ophthalmol. 2005; 139 (1): 179–81. doi: 10.1016/j.ajo.2004.06.091</mixed-citation></citation-alternatives></ref><ref id="cit24"><label>24</label><citation-alternatives><mixed-citation xml:lang="ru">Dhimitri K.C., McGwin G.Jr., McNeal S.F., et al. Symptoms of musculoskeletal disorders in ophthalmologists. Am. J. Ophthalmol. 2005; 139 (1): 179–81. doi: 10.1016/j.ajo.2004.06.091</mixed-citation><mixed-citation xml:lang="en">Chatterjee A., Ryan W.G., Rosen E.S. Back pain in ophthalmologists. Eye (Lond). 1994; 8 (4): 473–4. doi: 10.1038/eye.1994.112</mixed-citation></citation-alternatives></ref><ref id="cit25"><label>25</label><citation-alternatives><mixed-citation xml:lang="ru">Chatterjee A., Ryan W.G., Rosen E.S. Back pain in ophthalmologists. Eye (Lond). 1994; 8 (4): 473–4. doi: 10.1038/eye.1994.112</mixed-citation><mixed-citation xml:lang="en">Siebelmann S., Steven P., Hoset D., et al. Advantages of microscope-integrated intraoperative online optical coherence tomography: usage in Boston keratoprosthesis type I surgery. J. Biomed. Ort. 2016; 21 (1): 16005. doi: 10.1117/1.JBO.21.1.016005</mixed-citation></citation-alternatives></ref><ref id="cit26"><label>26</label><citation-alternatives><mixed-citation xml:lang="ru">Siebelmann S., Steven P., Hoset D., et al. Advantages of microscope-integrated intraoperative online optical coherence tomography: usage in Boston keratoprosthesis type I surgery. J. Biomed. Ort. 2016; 21 (1): 16005. doi: 10.1117/1.JBO.21.1.016005</mixed-citation><mixed-citation xml:lang="en">Pershin K.B., Pashinova N.F., Tsygankov A.Yu., Cherkashina A.V. The first experience of using the Verion system for implantation of toric IOLs in patients with cataracts and astigmatism in the Russian Federation. Cataract and refractive surgery, 2016 (1): 20–4 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit27"><label>27</label><citation-alternatives><mixed-citation xml:lang="ru">Першин К.Б., Пашинова Н.Ф., Цыганков А.Ю., Черкашина А.В. Первый опыт применения системы Verion при имплантации торических ИОЛ у пациентов с катарактой и астигматизмом в Российской Федерации. Катарактальная и рефракционная хирургия. 2016 (1): 20–4.</mixed-citation><mixed-citation xml:lang="en">Weinstock R.J., Diakonis V.F., Schwartz A.J., Weinstock A.J. Heads-up cataract surgery: complication rates, surgical duration, and comparison with traditional microscopes. J. Refract. Surg. 2019; 35 (5): 318–22. doi: 10.3928/1081597x20190410-02</mixed-citation></citation-alternatives></ref><ref id="cit28"><label>28</label><citation-alternatives><mixed-citation xml:lang="ru">Weinstock R.J., Diakonis V.F., Schwartz A.J., Weinstock A.J. Heads-up cataract surgery: complication rates, surgical duration, and comparison with traditional microscopes. J. Refract. Surg. 2019; 35 (5): 318–22. doi: 10.3928/1081597x20190410-02</mixed-citation><mixed-citation xml:lang="en">Belykh E., Xiaochun Z., Claudio C., et al. Laboratory evaluation of a robotic operative microscope — visualization platform for neurosurgery. Cureus. 2018; 10 (7): e 3073. doi: 10.7759/cureus.3072</mixed-citation></citation-alternatives></ref><ref id="cit29"><label>29</label><citation-alternatives><mixed-citation xml:lang="ru">Belykh E., Xiaochun Z., Claudio C., et al. Laboratory evaluation of a robotic operative microscope — visualization platform for neurosurgery. Cureus. 2018; 10 (7): e 3073. doi: 10.7759/cureus.3072</mixed-citation><mixed-citation xml:lang="en">Mamalis N. Correction of astigmatism during cataract surgery. J. Refract. Cataract Surgery. 2009; 35 (3): 403–4. doi: 10.3928/1081597X-20100526-01</mixed-citation></citation-alternatives></ref><ref id="cit30"><label>30</label><citation-alternatives><mixed-citation xml:lang="ru">Mamalis N. Correction of astigmatism during cataract surgery. J. Refract. Cataract Surgery. 2009; 35 (3): 403–4. doi: 10.3928/1081597X-20100526-01</mixed-citation><mixed-citation xml:lang="en">Cha D., Kang S.Y., Kim S.-H., Song J.-S, Kim H.-M. New axis-marking method for a toric intraocular lens: mapping method. J. Refract. Surg. 2011; 27 (5): 375–9. doi: 10.3928/1081597X-20101005-01</mixed-citation></citation-alternatives></ref><ref id="cit31"><label>31</label><citation-alternatives><mixed-citation xml:lang="ru">Cha D., Kang S.Y., Kim S.-H., Song J.-S, Kim H.-M. New axis-marking method for a toric intraocular lens: mapping method. J. Refract. Surg. 2011; 27 (5): 375–9. doi: 10.3928/1081597X-20101005-01</mixed-citation><mixed-citation xml:lang="en">Mascitelli J.R., Schlachter L., Chartrain A.G., et al. Navigation-linked heads-up display in intracranial surgery: early experience. Oper. Neurosurg. (Hagerstown). 2018; 15 (2): 184–93. doi: 10.1093/ons/opx205</mixed-citation></citation-alternatives></ref><ref id="cit32"><label>32</label><citation-alternatives><mixed-citation xml:lang="ru">Mascitelli J.R., Schlachter L., Chartrain A.G., et al. Navigation-linked heads-up display in intracranial surgery: early experience. Oper. Neurosurg. (Hagerstown). 2018; 15 (2): 184–93. doi: 10.1093/ons/opx205</mixed-citation><mixed-citation xml:lang="en">Bickerton R., Nassimizadeh A.K., Ahmed S. Three-dimensional endoscopy: the future of nasoendoscopic training. Laryngoscope. 2019; 129 (6): 1280–5. doi: 10.1002/lary.27812</mixed-citation></citation-alternatives></ref><ref id="cit33"><label>33</label><citation-alternatives><mixed-citation xml:lang="ru">Bickerton R., Nassimizadeh A.K., Ahmed S. Three-dimensional endoscopy: the future of nasoendoscopic training. Laryngoscope. 2019; 129 (6): 1280–5. doi: 10.1002/lary.27812</mixed-citation><mixed-citation xml:lang="en">Rose A.S., Kim H., Fuchs H., Frahm J.M. Development of augmented-reality applications in otolaryngology-head and neck surgery. Laryngoscope. 2019; 129 (3): 1–11. doi: 10.1002/lary.28098</mixed-citation></citation-alternatives></ref><ref id="cit34"><label>34</label><citation-alternatives><mixed-citation xml:lang="ru">Rose A.S., Kim H., Fuchs H., Frahm J.M. Development of augmented-reality applications in otolaryngology-head and neck surgery. Laryngoscope. 2019; 129 (3): 1–11. doi: 10.1002/lary.28098</mixed-citation><mixed-citation xml:lang="en">Bosc R., Fitoussi A., Hersant B., Dao T.H., Meningaud J.P. Intraoperative augmented reality with heads-up displays in maxillofacial surgery: a systematic review of the literature and a classification of relevant technologies. Int. J. Oral. Maxilllofacillac Surg. 2019; 48 (1): 132–9. doi: 10.1016/j.ijom.2018.09.010</mixed-citation></citation-alternatives></ref><ref id="cit35"><label>35</label><citation-alternatives><mixed-citation xml:lang="ru">Bosc R., Fitoussi A., Hersant B., Dao T.H., Meningaud J.P. Intraoperative augmented reality with heads-up displays in maxillofacial surgery: a systematic review of the literature and a classification of relevant technologies. Int. J. Oral. Maxilllofacillac Surg. 2019; 48 (1): 132–9. doi: 10.1016/j.ijom.2018.09.010</mixed-citation><mixed-citation xml:lang="en">Fotouhi J., Fuerst B., Lee S.C., et al. Interventional 3D augmented reality for orthopedic and trauma surgery. In: 6th Annual Meeting of the International Society for Computer Assisted Orthopedic Surgery (CAOS). 2016.</mixed-citation></citation-alternatives></ref><ref id="cit36"><label>36</label><citation-alternatives><mixed-citation xml:lang="ru">Fotouhi J., Fuerst B., Lee S.C., et al. Interventional 3D augmented reality for orthopedic and trauma surgery. In: 6th Annual Meeting of the International Society for Computer Assisted Orthopedic Surgery (CAOS). 2016.</mixed-citation><mixed-citation xml:lang="en">Weinstock R.J., Desai N. Heads-up cataract surgery with the TrueVision 3D display system. Surgical Techniques in Ophthalmology. Jaypee Medical Publishers. 2010; 1: 24–127. doi: 10.17925/EOR.2019.13.1.31</mixed-citation></citation-alternatives></ref><ref id="cit37"><label>37</label><citation-alternatives><mixed-citation xml:lang="ru">Weinstock R.J., Desai N. Heads-up cataract surgery with the TrueVision 3D display system. Surgical Techniques in Ophthalmology. Jaypee Medical Publishers. 2010; 1: 24–127. doi: 10.17925/EOR.2019.13.1.31</mixed-citation><mixed-citation xml:lang="en">Weinstock R.J. Operate with your head up. Cataract Refract. Surg. Today. 2011. Available at: https://crstodayeurope.com/articles/2011-apr/operate-withyour-head-up/ (accessed 27 Januar 2022).</mixed-citation></citation-alternatives></ref><ref id="cit38"><label>38</label><citation-alternatives><mixed-citation xml:lang="ru">Weinstock R.J. Operate with your head up. Cataract Refract. Surg. Today. 2011. Available at: https://crstodayeurope.com/articles/2011-apr/operate-withyour-head-up/ (accessed 27 Januar 2022).</mixed-citation><mixed-citation xml:lang="en">Weinstock R.J., Diakonis V.F., Schwartz A.J., Weinstock A.J. Heads-up cataract surgery: complication rates, surgical duration, and comparison with traditional microscopes. J. Refract Surg. 2019; 35 (5): 318–22. doi: 10.3928/1081597X20190410-02</mixed-citation></citation-alternatives></ref><ref id="cit39"><label>39</label><citation-alternatives><mixed-citation xml:lang="ru">Weinstock R.J., Diakonis V.F., Schwartz A.J., Weinstock A.J. Heads-up cataract surgery: complication rates, surgical duration, and comparison with traditional microscopes. J. Refract Surg. 2019; 35 (5): 318–22. doi: 10.3928/1081597X20190410-02</mixed-citation><mixed-citation xml:lang="en">Leica Microsystems. IOL Guidance Systems. IOLcompass &amp; 3D TrueGuide. Available at: https://downloads.leica-microsystems.com/IOLcompass/ Brochures/IOL%20guidance%20brochure_en.pdf (accessed 5 Nov. 2022).</mixed-citation></citation-alternatives></ref><ref id="cit40"><label>40</label><citation-alternatives><mixed-citation xml:lang="ru">Leica Microsystems. IOL Guidance Systems. IOLcompass &amp; 3D TrueGuide. Available at: https://downloads.leica-microsystems.com/IOLcompass/ Brochures/IOL%20guidance%20brochure_en.pdf (accessed 5 Nov. 2022).</mixed-citation><mixed-citation xml:lang="en">Mohamed Y.H., Uematsu M., Inoue D., Kitaoka T. First experience of nDSAEK with heads-up surgery: a case report. Medicine (Baltimore). 2017; 96 (19): e 6906. doi: 10.1097/MD.0000000000006906</mixed-citation></citation-alternatives></ref><ref id="cit41"><label>41</label><citation-alternatives><mixed-citation xml:lang="ru">Mohamed Y.H., Uematsu M., Inoue D., Kitaoka T. First experience of nDSAEK with heads-up surgery: a case report. Medicine (Baltimore). 2017; 96 (19): e 6906. doi: 10.1097/MD.0000000000006906</mixed-citation><mixed-citation xml:lang="en">Hamasaki I., Shibata K., Shimizu T., et al. Lights-out surgery for strabismus using a heads-up 3D vision system. Acta Med. Okayama. 2019; 73 (3): 229–33. doi: 10.18926/AMO/56865</mixed-citation></citation-alternatives></ref><ref id="cit42"><label>42</label><citation-alternatives><mixed-citation xml:lang="ru">Hamasaki I., Shibata K., Shimizu T., et al. Lights-out surgery for strabismus using a heads-up 3D vision system. Acta Med. Okayama. 2019; 73 (3): 229–33. doi: 10.18926/AMO/56865</mixed-citation><mixed-citation xml:lang="en">Dutra-Medeiros M., Nascimento J., Henriques J., et al. Three-dimensional head-mounted display system for ophthalmic surgical procedures. Retina. 2017; 37 (7): 1411–4. doi: 10.1097/IAE.0000000000001514</mixed-citation></citation-alternatives></ref><ref id="cit43"><label>43</label><citation-alternatives><mixed-citation xml:lang="ru">Dutra-Medeiros M., Nascimento J., Henriques J., et al. Three-dimensional head-mounted display system for ophthalmic surgical procedures. Retina. 2017; 37 (7): 1411–4. doi: 10.1097/IAE.0000000000001514</mixed-citation><mixed-citation xml:lang="en">Dutra-Medeiros M., Moura-Coelho N., Nascimento J., et al. Correspondence three-dimensional (3D) head-mounted display systems in ophthalmic surgery — first reports. Retina. 2017; 37 (7): 1411–4. doi: 10.1097/IAE.0000000000001514</mixed-citation></citation-alternatives></ref><ref id="cit44"><label>44</label><citation-alternatives><mixed-citation xml:lang="ru">Dutra-Medeiros M., Moura-Coelho N., Nascimento J., et al. Correspondence three-dimensional (3D) head-mounted display systems in ophthalmic surgery — first reports. Retina. 2017; 37 (7): 1411–4. doi: 10.1097/IAE.0000000000001514</mixed-citation><mixed-citation xml:lang="en">Lowenstein A., Schneider R., Barak A. First look: a head-mounted OR display. Review of ophthalmology. 2019; 1–5. Available at: https://www. reviewofophthalmology.com/article/first-look-a-headmounted-or-display</mixed-citation></citation-alternatives></ref><ref id="cit45"><label>45</label><citation-alternatives><mixed-citation xml:lang="ru">Lowenstein A., Schneider R., Barak A. First look: a head-mounted OR display. Review of ophthalmology. 2019; 1–5. Available at: https://www.reviewofophthalmology.com/article/first-look-a-headmounted-or-display</mixed-citation><mixed-citation xml:lang="en">Korot E., Thanos A., Todorich B., et al. Use of the Avegant Glyph head-mounted virtual retinal projection display to perform vitreoretinal surgery. J. Vitreoretin Dis. Available at: https://journals.sagepub.com/ doi/10.1177/2474126417738613 (accessed 28 December).</mixed-citation></citation-alternatives></ref><ref id="cit46"><label>46</label><citation-alternatives><mixed-citation xml:lang="ru">Korot E., Thanos A., Todorich B., et al. Use of the Avegant Glyph head-mounted virtual retinal projection display to perform vitreoretinal surgery. J. Vitreoretin Dis. Available at: https://journals.sagepub.com/ doi: 10.1177/2474126417738613 (accessed 28 December).</mixed-citation><mixed-citation xml:lang="en">Mendez B.M., Chiodo M.V., Vandevender D., Patel P.A. Heads-up 3D microscopy: an ergonomic and educational approach to microsurgery. Plast. Reconstr. Surg. Glob. Open. 2016; 4(5): e717. doi: 10.1097/ GOX.0000000000000727</mixed-citation></citation-alternatives></ref><ref id="cit47"><label>47</label><citation-alternatives><mixed-citation xml:lang="ru">Mendez B.M., Chiodo M.V., Vandevender D., Patel P.A. Heads-up 3D microscopy: an ergonomic and educational approach to microsurgery. Plast. Reconstr. Surg. Glob. Open. 2016; 4(5): e717. doi: 10.1097/ GOX.0000000000000727</mixed-citation><mixed-citation xml:lang="en">Eckardt C., Paulo E.B. Heads-up surgery for vitreoretinal procedures: an experimental and clinical study. Retina, 2016 36 (1): 137–47. doi: 10.1097/ IAE.0000000000000689</mixed-citation></citation-alternatives></ref><ref id="cit48"><label>48</label><citation-alternatives><mixed-citation xml:lang="ru">Eckardt C., Paulo E.B. Heads-up surgery for vitreoretinal procedures: an experimental and clinical study. Retina, 2016 36 (1): 137–47. doi: 10.1097/ IAE.0000000000000689</mixed-citation><mixed-citation xml:lang="en">Freeman W.R., Chen K.C., Ho J., et al. Resolution, depth of field, and physician satisfaction during digitally assisted vitreoretinal surgery. Retina. 2019; 39 (9): 1768–71. doi: 10.1097/IAE.0000000000002236</mixed-citation></citation-alternatives></ref><ref id="cit49"><label>49</label><citation-alternatives><mixed-citation xml:lang="ru">Freeman W.R., Chen K.C., Ho J., et al. Resolution, depth of field, and physician satisfaction during digitally assisted vitreoretinal surgery. Retina. 2019; 39 (9): 1768–71. doi: 10.1097/IAE.0000000000002236</mixed-citation><mixed-citation xml:lang="en">Yoshihiro Y. Seeing the world through 3-D glasses: Grab some pearls for the coming world of 3-D heads-up surgery. Retina Today. Available at: https:// assets.bmctoday.net/retinatoday/pdfs/1016RT_Cover_Yonekawa.pdf</mixed-citation></citation-alternatives></ref><ref id="cit50"><label>50</label><citation-alternatives><mixed-citation xml:lang="ru">Yoshihiro Y. Seeing the world through 3-D glasses: Grab some pearls for the coming world of 3-D heads-up surgery. Retina Today. Available at: https://assets.bmctoday.net/retinatoday/pdfs/1016RT_Cover_Yonekawa.pdf</mixed-citation><mixed-citation xml:lang="en">Shuhaiber J. H. Augmented reality in surgery. Arch. Surg. 2004; 139 (2): 170–4. doi: 10.1001/archsurg.139.2.170</mixed-citation></citation-alternatives></ref><ref id="cit51"><label>51</label><citation-alternatives><mixed-citation xml:lang="ru">Shuhaiber J. H. Augmented reality in surgery. Arch. Surg. 2004; 139 (2): 170–4. doi: 10.1001/archsurg.139.2.170</mixed-citation><mixed-citation xml:lang="en">Shuhaiber J. H. Augmented reality in surgery. Arch. Surg. 2004; 139 (2): 170–4. doi: 10.1001/archsurg.139.2.170</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
