<?xml version="1.0" encoding="UTF-8"?>
<!DOCTYPE article PUBLIC "-//NLM//DTD JATS (Z39.96) Journal Publishing DTD v1.3 20210610//EN" "JATS-journalpublishing1-3.dtd">
<article article-type="research-article" dtd-version="1.3" xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink" xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance" xml:lang="ru"><front><journal-meta><journal-id journal-id-type="publisher-id">helmholtzeyeinstitute</journal-id><journal-title-group><journal-title xml:lang="ru">Российский офтальмологический журнал</journal-title><trans-title-group xml:lang="en"><trans-title>Russian Ophthalmological Journal</trans-title></trans-title-group></journal-title-group><issn pub-type="ppub">2072-0076</issn><issn pub-type="epub">2587-5760</issn><publisher><publisher-name>Real time Publishers</publisher-name></publisher></journal-meta><article-meta><article-id pub-id-type="doi">10.21516/2072-0076-2021-14-2-27-35</article-id><article-id custom-type="elpub" pub-id-type="custom">helmholtzeyeinstitute-652</article-id><article-categories><subj-group subj-group-type="heading"><subject>Research Article</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="ru"><subject>КЛИНИЧЕСКИЕ ИССЛЕДОВАНИЯ</subject></subj-group><subj-group subj-group-type="section-heading" xml:lang="en"><subject>CLINICAL STUDIES</subject></subj-group></article-categories><title-group><article-title>Перспективы применения тонометра ТВГД-02 для  ассистированного мониторинга внутриглазного давления  в домашней практике</article-title><trans-title-group xml:lang="en"><trans-title>Prospects of using the TVGD-02 tonometer for assisted  monitoring of intraocular pressure at home</trans-title></trans-title-group></title-group><contrib-group><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Филиппова</surname><given-names>О. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Filippova</surname><given-names>O. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Ольга Маратовна Филиппова— канд. мед. наук, научный сотрудник отдела глаукомы</p><p>ул. Садовая-Черногрязская, д. 14/19, Москва, 105062</p></bio><bio xml:lang="en"><p>Olga M. Filippova — Cand. of Med. Sci., research associate, department of glaucoma</p><p>14/19, Sadovaya-Chernogryazskaya St., Moscow, 105062</p></bio><email xlink:type="simple">changa2@mail.ru</email><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Бессмертный</surname><given-names>А. М.</given-names></name><name name-style="western" xml:lang="en"><surname>Bessmertny</surname><given-names>A. M.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Александр Маркович Бессмертный— д-р мед. наук, старший научный сотрудник отдела глаукомы</p><p>ул. Садовая-Черногрязская, д. 14/19, Москва, 105062</p></bio><bio xml:lang="en"><p>Alexander M. Bessmertny — Dr. of Med. Sci., senior researcher, department of glaucoma</p><p>14/19, Sadovaya-Chernogryazskaya St., Moscow, 105062</p></bio><xref ref-type="aff" rid="aff-1"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Кузин</surname><given-names>М. Н.</given-names></name><name name-style="western" xml:lang="en"><surname>Kuzin</surname><given-names>M. N.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Михаил Николаевич Кузин — инженер по сертификации</p><p>ул. Высоковольтная, д. 48, корпус Б, Рязань, 390029</p></bio><bio xml:lang="en"><p> Mikhail N. Kuzin— certification engineer</p><p>Bldg B, 48, Vysokovoltnaya St., Ryazan, 390029</p></bio><xref ref-type="aff" rid="aff-2"/></contrib><contrib contrib-type="author" corresp="yes"><name-alternatives><name name-style="eastern" xml:lang="ru"><surname>Петров</surname><given-names>С. Ю.</given-names></name><name name-style="western" xml:lang="en"><surname>Petrov</surname><given-names>S. Yu.</given-names></name></name-alternatives><bio xml:lang="ru"><p>Сергей Юрьевич Петров— д-р мед. наук, профессор, начальник отдела глаукомы</p><p>ул. Садовая-Черногрязская, д. 14/19, Москва, 105062</p></bio><bio xml:lang="en"><p>Sergey Yu. Petrov — Dr. of Med. Sci., professor, head, department of glaucoma</p><p>14/19, Sadovaya-Chernogryazskaya St., Moscow, 105062</p></bio><xref ref-type="aff" rid="aff-1"/></contrib></contrib-group><aff-alternatives id="aff-1"><aff xml:lang="ru"><institution>ФГБУ «НМИЦ глазных болезней им. Гельмгольца» Минздрава России</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Helmholtz National Medical Research Center of Eye Diseases</institution><country>Russian Federation</country></aff></aff-alternatives><aff-alternatives id="aff-2"><aff xml:lang="ru"><institution>Научно-технический центр «АО "Елатомский приборный завод"»</institution><country>Россия</country></aff><aff xml:lang="en"><institution>Research and Development Center of Yelatma Instrument Making Enterprise</institution><country>Russian Federation</country></aff></aff-alternatives><pub-date pub-type="collection"><year>2021</year></pub-date><pub-date pub-type="epub"><day>17</day><month>06</month><year>2021</year></pub-date><volume>14</volume><issue>2</issue><fpage>27</fpage><lpage>35</lpage><permissions><copyright-statement>Copyright &amp;#x00A9; Филиппова О.М., Бессмертный А.М., Кузин М.Н., Петров С.Ю., 2021</copyright-statement><copyright-year>2021</copyright-year><copyright-holder xml:lang="ru">Филиппова О.М., Бессмертный А.М., Кузин М.Н., Петров С.Ю.</copyright-holder><copyright-holder xml:lang="en">Filippova O.M., Bessmertny A.M., Kuzin M.N., Petrov S.Y.</copyright-holder><license xml:lang="ru" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>Данная работа распространяется под лицензией Creative Commons Attribution 4.0.</license-p></license><license xml:lang="en" license-type="creative-commons-attribution" xlink:href="https://creativecommons.org/licenses/by/4.0/" xlink:type="simple"><license-p>This work is licensed under a Creative Commons Attribution 4.0 License.</license-p></license></permissions><self-uri xlink:href="https://roj.igb.ru/jour/article/view/652">https://roj.igb.ru/jour/article/view/652</self-uri><abstract><p>Цель работы — оценка безопасности и удобства самостоятельного применения тонометра внутриглазного давления ТВГД-02 пользователями в домашних условиях без привлечения медицинских работников. Материал и методы.42 человека сформировали 30 пар: пользователь-пациент и пользователь-ассистент. В 9 парах каждый участник исполнял роль и пациента, и ассистента. Участники самостоятельно обучались в домашних условиях методике транспальпебрального измерения внутриглазного давления (ВГД), проводили тестирование на контрольном устройстве прибора и измерение ВГД пользователю-пациенту. В анкете пользователи отмечали удобство и безопасность применения тонометра по 5-балльной шкале. Результаты. Среди пользователей-ассистентов были представлены лица (средний возраст — 59,68 ± 17,20 [22; 83] года) с различным образовательным уровнем. Из пользователей-пациентов (60,64 ± 17,10 [22; 82] года) в 82,14 % в исследовании принимали участие лица с глазной патологией, в 35,7 % случаев у пациентов имелась глаукома с сопутствующей офтальмопатологией. В 100 % случаев участники смогли самостоятельно разобраться в том, как правильно подготовить тонометр к работе и выполнить измерение ВГД. Точность и воспроизводимость результатов измерения значительно повышались с усовершенствованием навыков работы с тонометром: в 1-й день разброс данных в серии измерений составлял для контрольного устройства 2,07 ± 1,70 [7; 0], а для офтальмотонуса пользователя-пациента — 2,89 ± 1,91 [8; 0] мм рт. ст., а на 5-й день точность измерений значительно возросла и этот показатель уменьшился до 1,21 ± 0,72 [2; 0] и 0,85 ± 0,69 [2; 0] мм рт. ст. соответственно. Пользователи оценили легкость выполнения различных этапов применения прибора от 4,21 ± 0,67 до 5,0 ± 0,0 балла. Заключение. Транспальпебральная тонометрия с помощью тонометра ТВГД-02 дает возможность адекватной оценки ВГД у пациентов при ассистированной тонометрии в домашней практике. Самостоятельное изучение информации о принципах работы прибора и методике его применения делает возможным приобретение навыков использования тонометра без участия медицинского персонала.</p></abstract><trans-abstract xml:lang="en"><p>Purpose: to evaluate the safety and convenience of self-using the intraocular pressure tonometer TVGD-02 at home with no participation of medical professionals. Material and methods. 42 people formed 30 pairs: a patient and an assistant. In 9 pairs, each person played both roles. The participants practiced the technique of transpalpebral measurement of intraocular pressure (IOP) at home, and, as assistants, measured IOP of their partner patients. All subjects were asked to fill in a questionnaire to evaluate the convenience and safety of the tonometer use by a 5-point system. Results. The assistant users, aged 22 to 83 (ave. 59.68 ± 17.20 years) had diverse educational levels. Of the patient users, aged 22 to 82 (ave. 60.64 ± 17.10 years), 82.14 % had ocular pathology, while 35.7 % had glaucoma with concomitant pathology. In 100 % of cases, the participants required no professional assistance to properly prepare the tonometer for operation and perform IOP measurement. The accuracy and reproducibility of measurement results significantly increased with the assistants’ gaining skills of operating the tonometer. On the 1st day, the data obtained in a series of measurements scattered for the control block within 2.07 ± 1.70 [7; 0] mm Hg, while the measured IOP of the patient scattered within 2.89 ± 19.10 [8; 0]. In contrast, on the 5th day, measurement accuracy increased significantly and the scatter dropped to 1.21 ± 0.72 [2; 0] and 0.85 ± 0.69 [2; 0] mm Hg, respectively. The users rated the ease of using the device at different staged from 4.21 ± 0.67 to 5.0 ± 0.0 points. Conclusion. Assisted transpalpebral tonometry with the TVGD-02 tonometer ensures an adequate assessment of IOP in patients at home. The principles of device operation and the technique can be learned and skills can be gained without the participation of medical personnel.</p></trans-abstract><kwd-group xml:lang="ru"><kwd>транспальпебральная тонометрия</kwd><kwd>внутриглазное давление</kwd><kwd>глаукома</kwd><kwd>самостоятельный контроль</kwd></kwd-group><kwd-group xml:lang="en"><kwd>transpalpebral tonometry</kwd><kwd>intraocular pressure</kwd><kwd>glaucoma</kwd><kwd>self-monitoring</kwd></kwd-group></article-meta></front><back><ref-list><title>References</title><ref id="cit1"><label>1</label><citation-alternatives><mixed-citation xml:lang="ru">Dabasia P.L., Lawrenson J.G., Murdoch I.E.Evaluation of a new rebound tonometer for self measurement of intraocular pressure. Br. J. Ophthalmol. 2016; 100: 1139–43. http://dx.doi.org/10.1136/bjophthalmol-2015-307674</mixed-citation><mixed-citation xml:lang="en">Dabasia P.L., Lawrenson J.G., Murdoch I.E.Evaluation of a new rebound tonometer for self measurement of intraocular pressure. Br. J. Ophthalmol. 2016; 100: 1139–43. http://dx.doi.org/10.1136/bjophthalmol-2015-307674</mixed-citation></citation-alternatives></ref><ref id="cit2"><label>2</label><citation-alternatives><mixed-citation xml:lang="ru">Gibbons F.M., Berlin M.S., Töteberg-Harms M.Twenty-four hour intraocular pressure measurements and home tonometry. Curr. Opin. Ophthalmol. 2018; Mar; 29 (2): 111–5. doi: 10.1097/ICU.0000000000000460</mixed-citation><mixed-citation xml:lang="en">Gibbons F.M., Berlin M.S., Töteberg-Harms M.Twenty-four hour intraocular pressure measurements and home tonometry. Curr. Opin. Ophthalmol. 2018; Mar; 29 (2): 111–5. doi: 10.1097/ICU.0000000000000460</mixed-citation></citation-alternatives></ref><ref id="cit3"><label>3</label><citation-alternatives><mixed-citation xml:lang="ru">Нестеров А.П. Глаукома. Москва: Мединформ; 2008.</mixed-citation><mixed-citation xml:lang="en">Nesterov A.P. Glauсoma. Moscow: Medinform ; 2008 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit4"><label>4</label><citation-alternatives><mixed-citation xml:lang="ru">Нероев В.В., Киселева О.А., Бессмертный А.М.Основные результаты мультицентрового исследования эпидемиологических особенностей первичной открытоугольной глаукомы в Российской Федерации. Российский офтальмологический журнал. 2013; 6 (3): 4–7.</mixed-citation><mixed-citation xml:lang="en">Neroev V.V., Kiseleva O.A., Bessmertny A.M.The main results of a multicenter study of epidemiological characteristics of primary open angle glaucoma in the Russian Federation. Russian ophthalmological journal. 2013; 3 (6): 4–7 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit5"><label>5</label><citation-alternatives><mixed-citation xml:lang="ru">Габдрахманов Л.М., Газизова И.Р., Селезнев А.В. и др.Психология глаукомного больного. Российский офтальмологический журнал. 2020; 13 (3): 92–6.</mixed-citation><mixed-citation xml:lang="en">Gabdrakhmanov L.M., Gazizova I.R., Seleznev A.V., et al.The psychology of a glaucoma patient. Russian ophthalmological journal. 2020; 13 (3): 92–6 (in Russian). https://doi.org/10.21516/2072-0076-2020- 13-3-92-96</mixed-citation></citation-alternatives></ref><ref id="cit6"><label>6</label><citation-alternatives><mixed-citation xml:lang="ru">Кушнаревич Н.Ю., Иомдина Е.Н., Бессмертный А.М., Кузин М.Н. Оценка точности и информативности измерения внутриглазного давления с помощью транспальпебральной тонометрии у пациентов в контактных линзах. Российский офтальмологический журнал. 2020; 13 (2): 23–8.</mixed-citation><mixed-citation xml:lang="en">Kushnarevich N.Yu., Iomdina E.N., Bessmertny A.M., Kuzin M.N. Estimation of the accuracy and informativeness of measuring intraocular pressure in patients with their contact lenses on by transpalpebral scleral tonometry. Russian ophthalmological journal. 2020; 13 (2): 23–8 (in Russian)]. https://doi.org/10.21516/2072-0076-2020-13-2-23-28</mixed-citation></citation-alternatives></ref><ref id="cit7"><label>7</label><citation-alternatives><mixed-citation xml:lang="ru">Илларионова А.Р., Пилецкий Н.Г.Исследование достоверности показаний тонометра для измерения внутриглазного давления через веко (ТГДЦ-01«ПРА»). РМЖ. Клиническая офтальмология. 2001; 2: 55–6.</mixed-citation><mixed-citation xml:lang="en">Illarionova A., Piletzky N. Research results of intraocular pressure reliability indication by transpalpebral tonometer (TGD-01 PRA). RMJ. Clinical ophthalmology. 2001; 2: 55–6 (in Russian)].</mixed-citation></citation-alternatives></ref><ref id="cit8"><label>8</label><citation-alternatives><mixed-citation xml:lang="ru">Филиппова О.М.Транспальпебральная тонометрия: новые возможности регистрации внутриглазного давления. Глаукома. 2004; 1: 54–6.</mixed-citation><mixed-citation xml:lang="en">Filippova O.M. Transpalpebral tonometry: new possibilities of intraocular pressure registration. Glaucoma. 2004; 1: 54–6 (in Russian).</mixed-citation></citation-alternatives></ref><ref id="cit9"><label>9</label><citation-alternatives><mixed-citation xml:lang="ru">Егоров Е.А., Романова Т.Б., Кац Д.В., Баева Н.Г., Алябьева Ж.Ю. Транспаль-пебральная тонометрия — перспективный метод контроля внутриглазного давления. РМЖ. Клиническая офтальмология. 2016; 2: 75–8.</mixed-citation><mixed-citation xml:lang="en">Egorov E.A.,Romanova T.B., Katz D.V., Baeva N.G., Alyabyeva Zh.Yu. Transpalpebral tonometry — the perspective method of the IOP control. RMJ. Clinical ophthalmology. 2016; 2: 75–8 (in Russian)]. https://doi.org/10.21689/2311-7729-2016-16-2-75-78</mixed-citation></citation-alternatives></ref><ref id="cit10"><label>10</label><citation-alternatives><mixed-citation xml:lang="ru">Аветисов С.Э., Еричев В.П., Антонов А.А.Диагностические возможности транспальпебральной тонометрии индикатором ИГД-03. Национальный журнал глаукома. 2016; 15 (3): 17–23.</mixed-citation><mixed-citation xml:lang="en">Avetisov E.S., Erichev V.P., Antonov A.A.Diagnostic capabilities of transpalpebral tonometry with IGD-03. National journal glaucoma. 2016; 15 (3): 17–23 (in Russian)].</mixed-citation></citation-alternatives></ref><ref id="cit11"><label>11</label><citation-alternatives><mixed-citation xml:lang="ru">Greene P.R., Sergienko N.M., Wang S.K. Review: measurement techniques for intraocular pressure. Optom. Open Access. 2016; 1: 3. https://doi.org/10.4172/2476-2075.1000118</mixed-citation><mixed-citation xml:lang="en">Greene P.R., Sergienko N.M., Wang S.K. Review: measurement techniques for intraocular pressure. Optom. Open Access. 2016; 1: 3. https://doi.org/10.4172/2476-2075.1000118</mixed-citation></citation-alternatives></ref><ref id="cit12"><label>12</label><citation-alternatives><mixed-citation xml:lang="ru">Wisse R., Peters N., Imhof S.M., van der Lelija A.Comparison of Diaton transpalpebral tonometer with applanation tonometry in keratoconus. Int. J. Ophthalmol. 2018 Mar.; 9 (3): 395–8. doi:10.18240/ijo.2016.03.12</mixed-citation><mixed-citation xml:lang="en">Wisse R., Peters N., Imhof S.M., van der Lelija A.Comparison of Diaton transpalpebral tonometer with applanation tonometry in keratoconus. Int. J. Ophthalmol. 2018 Mar.; 9 (3): 395–8. doi:10.18240/ijo.2016.03.12</mixed-citation></citation-alternatives></ref><ref id="cit13"><label>13</label><citation-alternatives><mixed-citation xml:lang="ru">Дыкин В.И., Иванищев К.В., Корнев Н.П., Михеев А.А., Соломаха В.Н. Тонометр внутриглазного давления динамического типа. Медицинская техника. 2013; 4 (280): 33–6.</mixed-citation><mixed-citation xml:lang="en">Dykin V.I., Ivanishchev K.V., Kornev N.P., Mikheev A.A., Solomakha V.N. Device for calibration of the TVGP-01 dynamic tonometr. Biomed. Eng. 2013; 47: 209–12 (in Russian)]. https://doi.org/10.1007/s10527-013-9373-2</mixed-citation></citation-alternatives></ref><ref id="cit14"><label>14</label><citation-alternatives><mixed-citation xml:lang="ru">Иомдина Е.Н., Клевцов Э.А., Иванищев К.В. и др. Экспериментальное моделирование как основа определения оптимальных параметров датчика для транспальпебральной тонометрии. Вестник офтальмологии. 2019; 135 (6): 27–32.</mixed-citation><mixed-citation xml:lang="en">Iomdina E.N., Klevtsov E.A., Ivanishchev K.V., et al. Experimental simulation for determining optimal design parameters of a transpalpebral tonometry sensor. Vestnik oftal'mologii. 2019; 135 (6): 27–32 (in Russian). https://doi.org/10.17116/oftalma201913506127</mixed-citation></citation-alternatives></ref></ref-list><fn-group><fn fn-type="conflict"><p>The authors declare that there are no conflicts of interest present.</p></fn></fn-group></back></article>
