Estimation of the accuracy and informativeness of measuring intraocular pressure in patients with their contact lenses on by transpalpebral scleral tonometry

https://doi.org/10.21516/2072-0076-2020-13-2-23-28

Abstract

Purpose: to compare the tonometry results obtained by transpalpebral scleral tonometry and pneumotonometry for patients with their contact lenses on. Material and methods. Intraocular pressure (IOP) was measured in 30 (60 eyes) patients with various refraction errors including 5 patients (10 eyes) aged 11–63 (45.0 ± 21.0) years with hyperopia of +1.75 to +9.0 D (+4.4 ± 2.6 D) and 25 patients (50 eyes) aged 12–57 (26.4 ± 13.5) years with myopia of -0.5 to -11.25 D (-4.4 ± 2.4 D). In most of cases patients used soft daily disposable contact lenses (spherical or multifocal). IOP was determined in both eyes of each patient using 1) transpalpebral scleral tonometry (EASYTON tonometer), and 2) corneal pneumotonometry. IOP was first measured when the patient was without their contact lenses, by both methods consecutively. 20 minutes after putting the lenses on, IOP was measured once again. Each measurement was taken three times and the average IOP value was determined. The data were analyzed using parametric statistics: the mean value and the standard deviation (M ± SD) of each parameter were calculated. Results. On average, patients without contact lenses showed transpalpebral IOP (IOPtr) of 16.3 ± 2.9 mmHg in the right eye (OD) and 16.6 ± 3.2 mmHg in the left eye (OS) and pneumotonometry IOP (IOPpn) of 16.0 ± 3.8 in OD and 15.6 ± 3.3 mmHg in OS. When the lenses were put on, the values of IOPtr stayed practically the same: 16.0 ± 3.9 mmHg in OD and 16.7 ± 3.1 mmHg in OS. IOPpn also changed insignificantly: 15.7 ± 2.9 mmHg in OD and 15.5 ± 2.8 mmHg in OS, but individual IOPpn data scattered more when the lenses were put on. IOPtr of hyperopic patients both with the lenses (19.5 ± 3.9 mmHg in OD and 19.7 ± 3.3 mmHg in OS) and without them (19.3 ± 2.8 mmHg in OD and 19.6 ± 3.1 mmHg in OS) was higher than IOPpn both with the lenses (14.0 ± 1.8 mmHg in OD and 14.2 ± 1.7 mmHg in OS) and without them (13.5 ± 2.7 mmHg in OD and 13.2 ± 1.6 mmHg in OS). A higher IOPtp in the hyperopic group seems more plausible because most patients in this group were significantly older than in myopic group. In hyperopic patients, IOPpn level in lenses tended to be higher than without them, while IOPtr was the same in either case. It may be due to the fact that contact lenses for high hyperopia are rather thick, which affects the air impact on the cornea during pneutonometry. In the myopic group the difference between IOPtr (15.2 ± 3.5 mmHg in OD and 16.0 ± 2.7 mmHg in OS) and IOPpn (16.1 ± 2.9 mmHg in OD and 15.9 ± 3.0 mmHg in OS) in lenses and IOPtr (15.7 ± 2.6 mmHg in OD and 15.9 ± 2.9 mmHg in OS) and IOPpn (16.6 ± 3.8 mmHg in OD and 16.1 ± 3.4 mmHg in OS) without them was insignificant. Conclusion. Transpalpebral scleral tonometry using EASYTON is an adequate method to measure IOP of patients with contact lenses on and can be the method of choice in a some of clinical cases, since its results and their repeatability are not affected by factors associated with the presence of a contact lens.

About the Authors

N. Yu. Kushnarevich
Helmholtz National Medical Research Center of Eye Diseases
Russian Federation

Nina Yu. Kushnarevich — Cand. of Med. Sci., senior researcher, department of refraction pathology, binocular vision and ophthalmoergonomics

14/19, Sadovaya-Chernogryazskaya St., Moscow, 105062



E. N. Iomdina
Helmholtz National Medical Research Center of Eye Diseases
Russian Federation

Elena N. Iomdina — Dr. of Biol. Sci., principal researcher department of refraction pathology, binocular vision and ophthalmoergonomics

14/19, Sadovaya-Chernogryazskaya St., Moscow, 105062



A. M. Bessmertny
Helmholtz National Medical Research Center of Eye Diseases
Russian Federation

Alexander M. Bessmertny — Dr. of Med. Sci., senior researcher, department of glaucoma

14/19, Sadovaya-Chernogryazskaya St., Moscow, 105062



M. N. Kuzin
Research and Development Center of Yelatma Instrument Making Enterprise, JSC
Russian Federation

Mikhail N. Kuzin — certification engineer

building B, 48, Vysokovoltnaya St., Ryazan, 390000



References

1. Nichols J.J., Fisher D. Contact lenses 2018. Contact Lens Spectrum. 2019 Jan; 34: 18–23. https://www.clspectrum.com/issues/2019/january-2019/contactlenses-2018

2. Shahbandeh M. Value of the global contact lens market from 2017 to 2024. 2018 Apr; 4. Available at https://www.statista.com/statistics/485820/global-valueof-the-contact-lens-market/

3. Alyaeva O.O., Ryabenko O.I., Tananakina E.M., Yushkova I.S. Zenlens scleral lenses for visual rehabilitation of patients with irregular cornea: a usage experience. Russian ophthalmological journal. 2018; 11 (4): 68–74 (in Russian). https://doi.org/10.21516/2072-0076-2018-11-4-68-74

4. Potter R. The history of hybrid contact lenses. Where these lenses started and where they are today. Contact Lens Spectrum. 2015 November; 30 (30): 32–5. Available at: https://www.clspectrum.com/issues/2015/november-2015/thehistory-of-hybrid-contact-lenses

5. Neroev V.V., Myagkov A.V., Guryanova O.V., Khandzhyan A.T., Yakunina A.I. Hybrid contact lenses for the correction of primary and induced ametropias. Russian ophthalmological journal. 2020; 13 (1): 102–7 (in Russian). https://doi.org/10.21516/2072-0076-2020-13-1-102-107

6. Milash S.V., Epishina M.V., Toloraya R.R. Modern optical methods of peripheral defocus correction. Russian ophthalmological journal. 2019; 12 (4): 92–8 (in Russian). https://doi.org/10.21516/2072-0076-2019-12-4-92-98

7. Aller T.A., Liu M., Wildsoet C.F. Myopia control with bifocal contact lenses: a randomized clinical trial. Optom Vis Sci. 2016; 93 (4): 344–52. doi: 10.1097/OPX.0000000000000808

8. Walline J., Greiner K., McVey M., Jones-Jordan L. Multifocal contact lens myopia control. Optom Vis Sci. 2013; 90 (11): 1207–1214. https://doi.org/10.1097/OPX.0000000000000036

9. Li S.M., Kang M.T., Wu S.S. Studies using concentric ring bifocal and peripheral add multifocal contact lenses to slow myopia progression in school-aged children: a meta-analysis. Ophthalmic Physiol. Opt. 2017; 37 (1): 51–9. https://doi.org/10.1111/opo.12332

10. Morgan P.B., Efron N., Woods C.A. An international survey of contact lens prescribing for presbyopia. Clin. Exp. Optom. 2011; 94: 87–92. doi: 10.1111/j.1444-0938.2010.00524

11. Shchuko A.G., Seliverstova N.N., Rogozhnikova E.A., Rozanova O.I. Advantages and disadvantages of multifocal contact lens correction of presbyopia in patients with myopic refraction. Ophthalmology in Russia. 2013; 10 (2): 31–4 (in Russian). https://doi.org/10.18008/1816-5095-2013-2-31-34

12. Shen L., Melles R.B., Metlapally Ravikanth, et al. The association of refractive error with glaucoma in a multiethnic population. Ophthalmology. 2016 Jan; 123 (1): 92–101. doi:10.1016/j.ophtha.2015.07.002

13. Kaufman P.L., Lu ̈tjen Drecoll E., Croft M.A. Presbyopia and glaucoma: two diseases, one pathophysiology? The 2017 Friedenwald Lecture. Invest. Ophthalmol. Vis. Sci. 2019; 60:1801–12. https://doi.org/10.1167/iovs.19-26899

14. Illarionova A., Piletzky N. Research results of intraocular pressure reliability indication by transpalpebral tonometer (TGD-01 PRA). RMJ. Clinical ophthalmology. 2001; 2: 55–6 (in Russian).

15. Wisse R., Peters N., Imhof S.M., van der Lelija A. Comparison of Diaton transpalpebral tonometer with applanation tonometry in keratoconus. Int. J. Ophthalmol. 2018 Mar.; 9 (3): 395–8 doi:10.18240/ijo.2016.03.12

16. Filippova O.M. Transpalpebral tonometry: new possibilities of intraocular pressure registration. Glaucoma. 2004; 1: 54–6 (in Russian).

17. Avetisov E.S., Erichev V.P., Antonov A.A. Diagnostic capabilities of transpalpebral tonometry with IGD-03. Russian journal of glaucoma. 2016; 15 (3): 17–23 (In Russian).

18. Dykin V.I., Ivanishchev K.V., Kornev N.P., Mikheev A.A., Solomakha V.N. Intraocular pressure dynamic type tonometer. Meditsinskaya tekhnika. 2013; 4 (280): 33–6 (in Russian).

19. Iomdina E.N., Klevtsov E.A., Ivanishchev K.V., et al. Experimental simulation for determining optimal design parameters of a transpalpebral tonometry sensor. Vestnik oftal'mologii. 2019; 135 (6): 27–32 (in Russian). https://doi.org/10.17116/oftalma201913506127

20. Rozhdestvenskaya M., Orlob J., Rüttimann D., et al. The advantage of transpalpebral scleral tonometry for individuals wearing contact lenses. Invest. Ophthalmol. Vis. Sci. July 2019; 60: 2428. https://iovs.arvojournals.org/article.aspx?articleid=2742564


Review

For citations:


Kushnarevich N.Yu., Iomdina E.N., Bessmertny A.M., Kuzin M.N. Estimation of the accuracy and informativeness of measuring intraocular pressure in patients with their contact lenses on by transpalpebral scleral tonometry. Russian Ophthalmological Journal. 2020;13(2):23-28. https://doi.org/10.21516/2072-0076-2020-13-2-23-28

Views: 2865


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2072-0076 (Print)
ISSN 2587-5760 (Online)