Preview

Russian Ophthalmological Journal

Advanced search

Prospects of application of high-tech carbon material as drainage in glaucoma surgery

https://doi.org/10.21516/2072-0076-2017-10-4-63-67

Abstract

Purpose. To conduct an experimental and clinical study of a hypotensive effect of implantation of an improved carbon drainage with an optimized sorption capacity. Material and methods. The study involved the eyes of 50 Chinchilla rabbits divided into 3 groups, depending on the diameter of the drainage, multifilament carbon: 150, 450 and 600 μm. The results were assessed over a 15-month period. Once a week, biomicroscopy and tonometry using a Maklakov tonometer (with the load of 10.0 G) was conducted. Once every 3 months, ultrasound and endothelial biomicroscopy was performed. Results. The ability of the developed drainage to significantly reduce IOP by improving the outflow of intraocular fluid was confirmed. Implantation was shown to cause no damage to corneal endothelium. Conclusion. The positive results obtained are an evidence of good prospects of using multifilament carbon for drainage in glaucoma surgery. For citations: Stepanov A.V., Zolkin P.I., Gamzaeva U.Sh. Prospects of application of high-tech carbon material as drainage in glaucoma surgery. Russian ophthalmological journal. 2017; 10 (4): 63-7. doi: 10.21516/2072-0076-2017-10-4-63-67 (In Russian).

About the Authors

A. V. Stepanov
Moscow Helmholtz Research Institute of Eye Diseases
Russian Federation


P. I. Zolkin
NII Grafit Research Institute of Structural Materials Based on Graphite
Russian Federation


U. Sh. Gamzaeva
Moscow Helmholtz Research Institute of Eye Diseases
Russian Federation


References

1. Астахов Ю.С., Егоров Е.А., Астахов С.Ю., Брезель Ю.А. Хирургическое лечение «рефрактерной» глаукомы. Клиническая офтальмология. 2006; 7(1): 25-7.

2. Бессмертный А.М., Червяков А.Ю. Применение имплантов в лечении рефрактерной глаукомы. Глаукома. 2002; 1(1): 44-7.

3. Прокофьева М.И. Современные хирургические подходы к лечению рефрактерной глаукомы (обзор литературы). Клиническая офтальмология. 2010; 11(3): 104-8.

4. Lieberman M.F., Ewing R.H. Drainage implant surgery for refractory glaucoma. Int. Ophthalmol. Clin. 1990; 30(3): 198-208.

5. Степанов А.В., Низов А.В. Отдаленные результаты имплантации клапана Ахмеда при посттравматической глаукоме. Глаукома. 2011; 10(2): 34-7.

6. Khan A.O., Al-Mobarak F. Comparison of polypropylene and silicone Ahmed valve survival 2 years following implantation in the first 2 years of life. British Journal of Ophthalmology. 2009; 93(6): 791-4. doi: 10.1136/bjo.2008.151258corr1.

7. Нероев В.В., Быков В.П., Золкин П.И., Кваша О.И., Белёвцева Т.А. Разработка дренажа из углеродной нити для лечения глаукомы на этапе исследований in vitro. Российский офтальмологический журнал. 2010; 3(3): 44-7.

8. Нероев В.В., Быков В.П., Кваша О.И., Белёвцева Т.А. Результаты нового метода микродренирования в эксперименте. Российский офтальмологический журнал. 2011; 4(2): 78-81.

9. Степанов А.В., Золкин П.И, Колычева С.Ю., Луговкина К.В., Гамзаева У.Ш. Предварительная клиническая оценка использования углеродной монофиламентной нити в дренажной хирургии посттравматической глаукомы. Российский офтальмологический журнал. 2014; 7(4): 46-51.

10. Золкин П.И., Островский В.С. Углеродные материалы в медицине. Москва: Изд-во Металлургиздат; 2014: 111-2.


Review

For citations:


Stepanov A.V., Zolkin P.I., Gamzaeva U.Sh. Prospects of application of high-tech carbon material as drainage in glaucoma surgery. Russian Ophthalmological Journal. 2017;10(4):63-67. (In Russ.) https://doi.org/10.21516/2072-0076-2017-10-4-63-67

Views: 598


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2072-0076 (Print)
ISSN 2587-5760 (Online)