Preview

Russian Ophthalmological Journal

Advanced search

Traumatic orbital fractures and various approaches to their treatment

https://doi.org/10.21516/2072-0076-2016-9-3-100-108

Abstract

Traumatic fractures of the orbit are fairly frequent injuries both in wartime and in peacetime. The purpose of the paper is to present the modern view of orbital lesions and their consequences, based on literary data and the authors’ personal experience. Surgical treatment consisting in the reconstruction of the original orbital shape and volume and in repositioning of orbital contents to their previous location is the only correct method of treating these injuries, which has to be resorted to as soon as possible. In cases of neglected fractures of orbital walls and edges, we need to refracture the bone, reposition and fix the broken orbital fragments, and then, concomitantly, reconstruct the orbital shape and volume as well as reposition the orbital contents in their original location. In patients with neglected orbital fractures, the results of surgical treatment (correction of eye position, enophthalmos, and double vision) are considerably poorer than those achieved after surgical treatment of fresh injuries. In reconstructing the orbital wall, autologous transplants are used (the cranial bone, the ilium, the bone of the front wall of the maxillary sinus, constal cartilage) as well as a variety of alloplastic materials // Russian Ophthalmological Journal, 2016; 3: 101-9. doi: 10.21516/2072-0076-2016-9-3-101-109.

About the Authors

R. . Ronchevich
Clinic for Plastic and Reconstructive Surgery, Clinical Centre of Serbia, Belgrade, Serbia
Russian Federation


Z. . Savkovich
Eye Hospital “Revida”, Belgrade, Serbia
Russian Federation


R. T. Nigmatullin
Russian Eye and Plastic Surgery Center, Ufa, Russian Federation
Russian Federation


References

1. Converse J.M., Smith B. Enophthalmos and diplopia in fracture of the orbital floor. Br. J.Plast. Surg. 1957; 9: 265-9.

2. Crikelair G.F., Rein J.M., Potter G.D., Cosman B. A critical look at the blowout Fracture. Plast. Reconstr. Surg.1972; 49: 374-9.

3. Smith B., Regan W.F.Jr. Blowout fracture of the orbit: Mechanism and correction of internal orbital fractures. Am. J. Ophthalmol. 1957; 44: 733-9.

4. Reny A., Striker M. Fractures de l'orbite. Indications ophthalmologiques dans les techniques operatories. Paris: Masson &Cie; 1969.

5. Fujino T., Makino K. Entrapment mechanism and ocular injury in orbital blowout fracture. Plast. Reconstr. Surg. 1980; 65: 571-4.

6. Dingman R.O., Converse J.M. The clinical management of facial injuries and fractures of the facial bones. In: Converse J.M., ed. Reconstructive Plastic Surgery. W.B. Saunders Company. 1977: 599-747.

7. Rumelt M.B., Ernest J.T. Isolated blowout fracture of the medial orbital wall with medial rectus entrapment. Am. J. Ophthalmol. 1972 ;73: 451-5.

8. Yano H., Nakano M., Anraku K., et al. A consecutuve rewiew of orbital blowout fractures and recommendations for comprehensive management. Plast. Reconst. Surg. 2009; 124:602-11.

9. Koorneef L. Current concepts on the management of orbital blowout fractures. Ann. Plast. Surg. 1982; 9: 185-200.

10. Koorneef L. Sectional anatomy of the orbit. Amsterdam: Aeolus Press; 1981.

11. Manson P.N., Clifford M.A., Iliff N.T., Morgan R. Mechanisms of global support and posttraumatic enophthalmos: I. The anatomy of the ligamentsling and its relation to intramuscular cone orbital fat. Plast. Reconstr. Surg. 1986; 77: 193-202.

12. Manson P.N ,Grivas A., Rosenbaum A., et al. Studies on Enophthalmos: II. The measurement of orbital injuries. Plast. Reconstr. Surg. 1986; 77; 203-14.

13. Manson P.N., Raus E.J., Iliff N.T. Deep orbital reconstruction for correction of posttraumatic enophthalmos. Clin. Plast. Surg. 1987; 14: 113-21.

14. Rončević R., Rončević D. Extensive, traumatic fractures of the orbit in war and peace time. J. Craniofac. Surg. 1999;10: 284-300.

15. Bite U., Jackson I.T., Forbest G.S., Gehring D.G. Orbital volume measurements in enophthalmos using three-dimensional CT imaging. Plast. Reconstr. Surg. 1985; 75: 502-7.

16. Rončević R., Stajčić Z. Surgical treatment of posttraumatic enophthalmos: A study of 72 patients Ann. Plast. Surg. 1994; 32: 288-94.

17. Armesto A., Ugrin M.C., Travelletti E., Schlaen A., Piantanida N. Hess Lancaster screen test with the head tilted: a useful test in the diagnosis of bilateral fourth nerve palsies. Eur J Ophthalmol. 2008 Mar-Apr;18(2):278-81.

18. Emery J.M., Noorden G.K., Schlernitzauer D.A. Management of orbital floor fractures. Am.J. Ophthalmol. 1972; 74: 299-306.

19. Lireman I.R. Loss vision associated with surgical treatment of zygomatic orbital floor fracture. Plast. Reconstr. Surg. 1981; 68: 94-7.

20. Nicholson D.H., Guzak S.V. Visual loss complicating repair orbital floor fractures Arch. Ophtahalmol. 1971; 86: 369-75.

21. Putterman A.M., Stevens T., Urist M.J. Nonsurgical management of blowour fractures of the orbital floor. Am. J. Ophthalmol. 1974; 77: 232-9.

22. Sacks A.C., Friedland J.A. Orbital fractures. Should they be explored early. Plast. Reconstr. Surg. 1979; 64: 190-3.

23. Horiono B. Recent correspondence on blow-out fracture. Intersekcijski sastanak. Vojnomedicinska akademija. Beograd; 1983.

24. Kawamoto H.K. Late posttraumatic enophthalmos: A correctable deformity. Plast. Reconstr. Surg. 1982; 69: 423-7.

25. Kohn R., Romano P.,E., Pulkin J.E. Lacrimal obstruction after migration of orbital floor implant Am. J. Ophthalmol. 1976; 82: 934-6.

26. Mauriello J.A., Hargrave S., Mostafavi R., Kapila R. Infection after insertion of alloplastics orbital floor impants. Am. J. Ophthalmol. 1994; 117: 246-52.

27. Jordan D.R., Onge P.S., Adrson R.L., Patrinely J.R., Nerad J.A. Complications associated with alloplastic implants used in orbital floor fracture repair. Ophthalmology. 1992; 99: 1600-8

28. Филатова И.А., Катаев М.Г., Быков В.П. Реконструкция дна орбиты комбинированным имплантантом из углерода и силикона. Офтальмохирургия. 1997; 4: 57-63.

29. Астахов Ю.С., Атласова Л.К., Николаенко В.П. Первый опыт использования пористых политетрафторэтиленовых имплантатов для закрытия травматических дефектов нижней стенки орбиты. Офтальмология. 2006; 2: 13-18.

30. Волков В.В. Офтальмохирургия с использованием полимеров. Санкт - Петербург: Гиппократ; 2009: 448-97.

31. Гундорова Р.А., Нероев В.В., Кашникова В.В. Травмы глаза. Москва: ГЭОТАР - Медиа; 2009:13-25.

32. Tenzel R.R., Miller G.R. Orbital blowout fracture repair, conjunctival approach. Am. J. Ophthalmol. 1971; 71: 1141-2.

33. Tessier P. The conjunctival approach in orbital fractures Plast. Reconst. Surg. 1973; 52: 656-9.

34. Longarce J.J., Kahl J.B., Wood R.W. Reconstruction of extensive defects in and about the orbit. Am. J. Ophthalmol. 1996; 61: 763-8.

35. Mustarde J.C. Repair and reconstruction in the orbital region: A practical guide. Edinburgh: Churchill Livingstone; 1980.

36. Ortiz-Monasterio F., Rodrigez A., Benavides A. A simple method for the correction of enophthalmos. Clin. Plast. Surg. 1987; 14: 169-75.


Review

For citations:


Ronchevich R., Savkovich Z., Nigmatullin R.T. Traumatic orbital fractures and various approaches to their treatment. Russian Ophthalmological Journal. 2016;9(3):100-108. (In Russ.) https://doi.org/10.21516/2072-0076-2016-9-3-100-108

Views: 676


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2072-0076 (Print)
ISSN 2587-5760 (Online)