Preview

Russian Ophthalmological Journal

Advanced search

Phacoemulsification and calculation of intraocular lenses in patients given keratorefractive surgery. Part 2

https://doi.org/10.21516/2072-0076-2021-14-4-118-125

Abstract

Effective rehabilitation of patients with cataracts who underwent keratorefractive surgeries requires that the optical power of the IOL be calculated correctly to avoid hyperopic error. The purpose of the 2nd part of the research (for the 1st part, see ROJ, 2021; 14 (2): 55–58) is to present the results of cataract phacoemulsification in patients subjected to keratorefractive surgery based on the author’s algorithm for calculating the optical power of the IOL. 
Material and methods. The algorithm used optical biometry with an IOL-Master device. The main technique of improving the accuracy of IOL calculation after keratorefractive operations has been to introduce amendments to standard IOL calculation formulas. This work proposes an alternative, which consists in using the Hoffer Q formula, as it is more consistent with changes in the anterior segment of the myopic eye after keratorefractive surgery than other basic. The main distinguishing feature of the Hoffer Q formula is that the corneal refraction is not converted into the radius of curvature but is applied directly as the optical power of a “thin lens”. 
Results. The empirical customized correction was +1.0 D with regard to the estimated planned postoperative refraction (for patients with initial myopia from -3 to -9 D). The use of the “thin lens” principle made it possible to extrapolate this formula and apply it after LASIK surgery and after radial keratotomy. 
Conclusion. The proposed technique of IOL calculation was implemented for cataract phacoemulsification in over 200 patients who underwent keratorefractive surgeries. No cases of hyperopic shift of postoperative refraction were noted. The deviation from the planned myopic refraction did not exceed 1.0 D.

About the Author

I. E. Ioshin
FSBU Clinical Hospital
Russian Federation

Igor E. Ioshin — Dr of Med. Sci., professor, head of the ophthalmology department of the center for ophthalmology

45, Losinoostrovskaya St., Moscow, 107143



References

1. Abulafia A., Hill W.E., Koch D.D., Wang L., Barrett G.D. Accuracy of the Barrett True-K formula for intraocular lens power prediction after laser in situ keratomileusis or photorefractive keratectomy for myopia. J. Cataract. Refract. Surg. 2016; 42: 363–9. https://doi:10.1016/j.jcrs.2015.11.039

2. Fram N.R., Masket S., Wang L. Comparison of intraoperative aberrometry, OCT-based IOL formula, Haigis-L, and Masket formulae for IOL power calculation after laser vision correction. Ophthalmology. 2015; 122: 1096–1101. https://doi.org/10.1016/j.ophtha.2015.01.027

3. Shammas H.J., Shammas M.C. No-history method of intraocular lens power calculation for cataract surgery after myopic laser in situ keratomileusis. J. Cataract Refract. Surg. 2007; 33: 31–6. https://doi:10.1016/j.jcrs.2006.08.045

4. Rosa N., Capasso L., Lanza M., et al. Reliability of a new correcting factor in calculating intraocular lens power after refractive corneal surgery. J. Cataract Refract. Surg. 2005; 31: 1020–4. https://doi.org/10.1016/j.jcrs.2004.10.055

5. Wang L., Booth M.A., Koch D.D. Comparison of intraocular lens power calculation methods in eyes that have undergone LASIK. Ophthalmology. 2004; 111: 1825–31. https://doi:10.1016/j.ophtha.2004.04.022

6. Ioshin I.E. Phacoemulsification and calculation of intraocular lenses in patients given keratorefractive surgery. Part 1. Russian ophthalmological journal. 2021; 14 (2): 55–8 (In Russian). https://doi.org/10.21516/2072-0076-2021-14-2-55-58

7. Olsen T. Sources of error in intraocular lens power calculation. J. Cataract Refract. Surg. 1992 Mar; 18 (2): 125–9. doi: 10.1016/s0886-3350(13)80917-0

8. Kiselyova T.N., Romanova L.I., Oganesyan O.G., Milash S.V., Penkina A.V. Optical eye biometry: principle and diagnostic capabilities of the method. Rossijskaya pediatricheskaya oftal'mologiya. 2016; 12(1): 35–42 (in Russian). http://dx.doi.org/10.18821/1993-1859-2017-12-1

9. Khodzhaev N.S., Bogush I.V. Methods of refractive errors eliminating in intraocular lens power calculation after corneal refractive surgery (review). Fyodorov journal of ophthalmic surgery. 2010; 2: 51–4 (In Russian).

10. Ioshin I.E. Intraocular correction of aphakia. Moscow: April; 2014 (In Russian).

11. Kulikov A.N., Kokareva E.V., Dzilikhov A.A. Effective lens position. A review. Fyodorov Journal of Ophthalmic Surgery. 2018; (1): 92–7 (In Russian). https://doi.org/10.25276/0235-4160-2018-1-92-97

12. Haigis W. Intraocular lens calculation after refractive surgery for myopia: Haigis-L formula. J. Cataract. Refract. Surg. 2008; 34: 1658–63. https://doi:10.1016/j.jcrs.2008.06.029

13. Holladay J.T. Cataract surgery in patients with previous keratorefractive surgery (RK, PRK, and LASIK). Ophthalmic Pract. 1997; 15: 238–44.

14. Stakheev A.A., Balashevich L.I. A new method of calculating intraocular lens power for patients with cataract undergone previously radial keratotomy. Fyodorov Journal of Ophthalmic Surgery. 2008; 2: 26–33 (In Russian).

15. Aramberri J. Intraocular lens power calculation after corneal refractive surgery: double-K method. J. Cataract Refract. Surg. 2003; 29: 2063–8. https://doi:10.1016/s0886-3350(03)00957-x

16. Li W., Spektor T., de Souza R.G., Koch D.D. Evaluation of total keratometry and its accuracy for intraocular lens power calculation in eyes after corneal refractive surgery. J. Cataract. Refract. Surg. 2019; 45: 1416–21. https://doi.org/10.016/j.jcrs.2019.05.020

17. Belikova E.I. Intraocular correction of presbyopia and astigmatism in patients after LASIK and radial keratotomy. Fyodorov journal of ophthalmic surgery. 2011; 3: 5–8 (In Russian).

18. Hoffer K.J. Intraocular lens power calculation after previous laser refractive surgery. J. Cataract. Refract. Surg. 2009; 35 (4): 759–65. https://doi.org/10.1016/j.jcrs.2009.01.005

19. Brandsdorfer A., Kang J.J. Improving accuracy for intraocular lens selection in cataract surgery. Curr. Opin. Ophthalmol. 2018; 29 (4): 323–7. https://doi:10.1097/ICU.0000000000000493

20. Ioshin I.E., Khachatryan G.T., Vigovskij A.V. Calculation of the optical power of IOL after keratorefractive surgery. Refrakcionnaya khirurgiya i oftal'mologiya. 2006; 6 (2): 28–32 (In Russian)


Review

For citations:


Ioshin I.E. Phacoemulsification and calculation of intraocular lenses in patients given keratorefractive surgery. Part 2. Russian Ophthalmological Journal. 2021;14(4):118-125. (In Russ.) https://doi.org/10.21516/2072-0076-2021-14-4-118-125

Views: 1298


Creative Commons License
This work is licensed under a Creative Commons Attribution 4.0 License.


ISSN 2072-0076 (Print)
ISSN 2587-5760 (Online)